:Ventilation Optimization for Reduction of Indoor Air Temperature of Main Transformer Room in Urban Indoor Substation by the Variational Method论文

:Ventilation Optimization for Reduction of Indoor Air Temperature of Main Transformer Room in Urban Indoor Substation by the Variational Method论文

本文主要研究内容

作者(2019)在《Ventilation Optimization for Reduction of Indoor Air Temperature of Main Transformer Room in Urban Indoor Substation by the Variational Method》一文中研究指出:Urban indoor substations are widely used for electrical power distribution in urban networks. However, they have the problems of heat dissipation and ventilation in main transformer room, which not only influence the thermal behavior of main transformer, but also decrease the lifetime, reliability, and precision of other electronic equipment. In this contribution, we developed a new ventilation optimization method based on the variational method to solve the aforementioned problems. First, we applied the minimum average temperature of indoor air as the optimization objective combined with some constrains to establish a Lagrange function, and employed the variational method to deduce some optimized governing equations that the optimum indoor patterns should meet the minimum indoor air average temperature. Finally, a typical main transformer room model was taken as an example to demonstrate the applications of the newly developed ventilation optimization method. It was concluded that the inflowing fresh air needed to sweep more area of heating walls to take away more heat, and reduce the average temperature of indoor air. Furthermore, based on the optimized air velocity distribution, we redesigned the ventilation arrangements and reduced the indoor average temperature prominently(from 337.44 K to 314.82 K), which can provide the guidance to design the ventilation of main transformer room to improve the reliability of electronic equipment in main transformer room.

Abstract

Urban indoor substations are widely used for electrical power distribution in urban networks. However, they have the problems of heat dissipation and ventilation in main transformer room, which not only influence the thermal behavior of main transformer, but also decrease the lifetime, reliability, and precision of other electronic equipment. In this contribution, we developed a new ventilation optimization method based on the variational method to solve the aforementioned problems. First, we applied the minimum average temperature of indoor air as the optimization objective combined with some constrains to establish a Lagrange function, and employed the variational method to deduce some optimized governing equations that the optimum indoor patterns should meet the minimum indoor air average temperature. Finally, a typical main transformer room model was taken as an example to demonstrate the applications of the newly developed ventilation optimization method. It was concluded that the inflowing fresh air needed to sweep more area of heating walls to take away more heat, and reduce the average temperature of indoor air. Furthermore, based on the optimized air velocity distribution, we redesigned the ventilation arrangements and reduced the indoor average temperature prominently(from 337.44 K to 314.82 K), which can provide the guidance to design the ventilation of main transformer room to improve the reliability of electronic equipment in main transformer room.

论文参考文献

  • [1].Electrical and magnetic properties of electrodeposited Fe-based alloys used for thin film transformer[J]. HOU XiaoWei,LIU ShiBin,YANG ShangLin,LI JuPing,GUO Bo.  Science China(Technological Sciences).2013(01)
  • [2].An active-passive beam current transformer[J]. ZHOU Wei SUN Baogen~* LU Ping WANG Xiaohui WANG Yong ZHANG Haiyan National Synchrotron Radiation Laboratory,University of Science and Technology of China,Hefei 230029,China.  Nuclear Science and Techniques.2008(02)
  • [3].ANN based pattern recognition of partial discharge in power transformer[J]. 王哲,蔡惟铮,陈学允.  Journal of Harbin Institute of Technology.1999(04)
  • [4].Application of fuzzy analytic hierarchy process and neural network in power transformer risk assessment[J]. 李卫国,俞乾,罗日成.  Journal of Central South University.2012(04)
  • [5].Application of extension method to fault diagnosis of transformer[J]. 邓宏贵,曹建,罗安,夏向阳.  Journal of Central South University of Technology.2007(01)
  • [6].Fault Characteristic Analysis of DC Pole-to-Pole Fault in Power Electronic Transformer[J]. JIANG Shan,FAN Chunju,HUANG Ning,ZENG Jie.  中国电机工程学报.2018(05)
  • [7].Transfer Characteristics of High-frequency Transformers Under Different Load Conditions[J]. QI Lei,LIU Chen,TANG Jian,CUI Xiang,ZHAO Guoliang,KANG Wei.  中国电机工程学报.2018(05)
  • [8].Research of a fractional-turn ratio saturable pulse transformer and its application in a microsecond-range pulse modulator[J]. 陈绒,杨建华,程新兵,潘子龙.  Plasma Science and Technology.2017(06)
  • [9].Testing methods for 1100 kV UHVDC transformer[J]. Thomas Hammer,Rene Wimmer,Karsten Loppach,Ronny Fritsche.  Global Energy Interconnection.2018(02)
  • [10].基于Borda数理论的变压器模糊风险评估模型(英文)[J]. 王有元,袁园,李剑.  高电压技术.2008(12)
  • 论文详细介绍

    论文作者分别是来自Journal of Thermal Science的,发表于刊物Journal of Thermal Science2019年05期论文,是一篇关于,Journal of Thermal Science2019年05期论文的文章。本文可供学术参考使用,各位学者可以免费参考阅读下载,文章观点不代表本站观点,资料来自Journal of Thermal Science2019年05期论文网站,若本站收录的文献无意侵犯了您的著作版权,请联系我们删除。

    标签:;  

    :Ventilation Optimization for Reduction of Indoor Air Temperature of Main Transformer Room in Urban Indoor Substation by the Variational Method论文
    下载Doc文档

    猜你喜欢