本文主要研究内容
作者(2019)在《Effect of Cooling Water Flow Path on the Flow and Heat Transfer in a 660 MW Power Plant Condenser》一文中研究指出:The effect of the cooling water flow path on the flow and heat transfer in a double tube-pass condenser for a 660 MW power plant unit was numerically investigated based on a porous medium model. The results were used to analyze the streamline, velocity, air mass fraction and heat transfer coefficient distributions. The simulations indicate that the cooling water flow path is important in large condensers. For the original tube arrangement, the heat transfer with the lower-upper cooling water flow path is better than that with the upper-lower cooling water flow path. The reason is that the steam cannot flow into the internal of upper tube bundle and the air fractions are higher in the upper tube bundle with the upper-lower cooling water flow path. An improvement tube arrangement was developed for the upper-lower cooling water flow path which reduced the back pressure by 0.47 kPa compared to the original scheme. Thus, the results show that the tube arrangements should differ for different cooling water flow paths and the condenser heat transfer can be improved for the upper-lower cooling water flow path by modifying the tube arrangement.
Abstract
The effect of the cooling water flow path on the flow and heat transfer in a double tube-pass condenser for a 660 MW power plant unit was numerically investigated based on a porous medium model. The results were used to analyze the streamline, velocity, air mass fraction and heat transfer coefficient distributions. The simulations indicate that the cooling water flow path is important in large condensers. For the original tube arrangement, the heat transfer with the lower-upper cooling water flow path is better than that with the upper-lower cooling water flow path. The reason is that the steam cannot flow into the internal of upper tube bundle and the air fractions are higher in the upper tube bundle with the upper-lower cooling water flow path. An improvement tube arrangement was developed for the upper-lower cooling water flow path which reduced the back pressure by 0.47 kPa compared to the original scheme. Thus, the results show that the tube arrangements should differ for different cooling water flow paths and the condenser heat transfer can be improved for the upper-lower cooling water flow path by modifying the tube arrangement.
论文参考文献
论文详细介绍
论文作者分别是来自Journal of Thermal Science的,发表于刊物Journal of Thermal Science2019年02期论文,是一篇关于,Journal of Thermal Science2019年02期论文的文章。本文可供学术参考使用,各位学者可以免费参考阅读下载,文章观点不代表本站观点,资料来自Journal of Thermal Science2019年02期论文网站,若本站收录的文献无意侵犯了您的著作版权,请联系我们删除。