万瑜:超超临界机组冷再管道故障原因分析与风险评估论文

本文主要研究内容

作者万瑜,王环丽,金传领,吕佳,马君鹏(2019)在《超超临界机组冷再管道故障原因分析与风险评估》一文中研究指出:某火力发电厂1000MW超超临界机组冷再管道在运行过程中发现多处支吊架故障,根据支吊架破坏情况和运行监控记录,启机暖管过程中预暖阀减温水产生泄漏,泄漏导致的水和管内蒸汽混合形成的高能柱塞流对冷再管道的冲击是管道支吊架损坏的根本原因。采用静荷载计算和模态分析的方法对管道进行了风险评估,发现管道最大一次应力增大了约110%、1阶固有频率下降了约60%,具有极大的安全风险。据此提出停机对管道进行损伤评估、支吊架故障处理以及事故的预防措施。

Abstract

mou huo li fa dian an 1000MWchao chao lin jie ji zu leng zai guan dao zai yun hang guo cheng zhong fa xian duo chu zhi diao jia gu zhang ,gen ju zhi diao jia po huai qing kuang he yun hang jian kong ji lu ,qi ji nuan guan guo cheng zhong yu nuan fa jian wen shui chan sheng xie lou ,xie lou dao zhi de shui he guan nei zheng qi hun ge xing cheng de gao neng zhu sai liu dui leng zai guan dao de chong ji shi guan dao zhi diao jia sun huai de gen ben yuan yin 。cai yong jing he zai ji suan he mo tai fen xi de fang fa dui guan dao jin hang le feng xian ping gu ,fa xian guan dao zui da yi ci ying li zeng da le yao 110%、1jie gu you pin lv xia jiang le yao 60%,ju you ji da de an quan feng xian 。ju ci di chu ting ji dui guan dao jin hang sun shang ping gu 、zhi diao jia gu zhang chu li yi ji shi gu de yu fang cuo shi 。

论文参考文献

  • [1].解析核电站管道支吊架设计及施工[J]. 李博闻.  化工管理.2017(23)
  • [2].火力发电厂汽水管道支吊架安装与调整[J]. 张文源.  科技创新与应用.2013(35)
  • [3].发电厂管道支吊架的检查与调整[J]. 刘维红,于国强,王振根.  电力安全技术.2006(09)
  • [4].在役管道支吊架状态异常对电厂安全运行的影响[J]. 郭延军,邵尉涛.  制冷空调与电力机械.2005(05)
  • [5].发电厂支吊架数据库设计[J]. 朱汉卫,胡玉清,徐泓.  电力建设.2003(05)
  • [6].热管道支吊架的热损情况与对策[J]. 莫松涛.  电力建设.2003(12)
  • [7].加强支吊架安装的质量管理[J]. 牟永录.  吉林电力技术.1991(06)
  • [8].限位支吊架的应用及选型[J]. 张儒用.  电力技术.1985(10)
  • [9].核电站支吊架强度核算问题研究[J]. 刘宏林.  产业与科技论坛.2019(01)
  • [10].管道支吊架间距计算标准比较分析[J]. 高晓频,张方绮,安永尧.  热力发电.2016(12)
  • 论文详细介绍

    论文作者分别是来自机械制造与自动化的万瑜,王环丽,金传领,吕佳,马君鹏,发表于刊物机械制造与自动化2019年02期论文,是一篇关于火力发电论文,冷再管道论文,支吊架论文,故障分析论文,风险评估论文,机械制造与自动化2019年02期论文的文章。本文可供学术参考使用,各位学者可以免费参考阅读下载,文章观点不代表本站观点,资料来自机械制造与自动化2019年02期论文网站,若本站收录的文献无意侵犯了您的著作版权,请联系我们删除。